Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.042
Filtrar
1.
Biomed Res Int ; 2024: 6670159, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38606199

RESUMO

Objective: This research study investigated the effect of new decontamination protocols on the bonding capacity of saliva-contaminated monolithic zirconia (MZ) ceramics cemented with two different monomer-containing self-adhesive resin cements. Materials and Methods: Standardized tooth preparations (4 mm. axial height) were performed for eighty human maxillary premolars under constant water cooling system. Eighty monolithic zirconia crowns (Whitepeaks Supreme Monolith) (n = 8/10 groups) were manufactured by CAD-CAM. Specimens were kept in the artificial saliva at pH = 7.3 for 1 minute at 37°C except control groups. The specimens have not been prealumina blasted and grouped according to cleaning methods and resin cements: control groups (C) (no saliva contamination + GPDM + 4-META (N) (CN) and 10-MDP (M) containing resin cement (CM), alumina blasted (AL) + GPDM + 4-META (ALN) and 10-MDP containing resin cement (ALM), zirconium oxide containing universal cleaning agent (IC) applied + GPDM + 4-META (N) (ICN) and 10-MDP containing resin cement (ICM), pumice (P) applied + GPDM + 4-META (PN) and 10-MDP containing resin cement (PM), and air-water spray (AW) applied + GPDM + 4-META (AWN) and 10-MDP containing resin cement (AWM)). Monobond Plus was applied to all surfaces for 40 seconds before cementation. The thermal cycle was applied at 5,000 cycles after cementation. The crowns were tested in tensile mode at a speed of 1 mm/min. The mode of failure was recorded. SEM examinations were carried out at different magnifications. Data were analyzed using rank-based Kruskal-Wallis and Mann-Whitney tests. Results: No significant differences were found between the surface treatments and between the two types of resin cements. Interaction effects between surface treatments and resin cements were found to be significant by two-way ANOVA analysis. ICM group resulted in significantly better bond strength results compared with CN. ICM was found to result in better bond strength results compared with PM. The combination of universal cleaning agent and 10-MDP containing resin cement had significantly the highest cementation bond strength values. The increasing order of mean tensile bond strength values of decontamination protocols was C < AW < P < AL < IC. The mean tensile bond strength of 10-MDP containing resin cement was slightly higher than GPDM + 4-META containing resin cement. Conclusions: Universal cleaning agents can be preferred as an efficient cleaning method with 10-MDP-containing cement after saliva contamination for better adhesive bond strength of 4 mm crown preparation height of monolithic zirconia ceramics.


Assuntos
Colagem Dentária , Metacrilatos , Cimentos de Resina , Humanos , Cimentos de Resina/química , Saliva , Descontaminação , Teste de Materiais , Zircônio/química , Cerâmica/química , Água/química , Resistência ao Cisalhamento , Propriedades de Superfície , Análise do Estresse Dentário
2.
Langmuir ; 40(15): 8271-8283, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38557053

RESUMO

Surface modification of lubricating coatings on biomedical devices is a pivotal strategy to improve the overall performance and clinical efficacy, significantly reducing friction between devices and human tissues and mitigating tissue damage during intervention and long-term implantation. Recently, various hydrophilic polymeric materials have been used for achieving surface functionalization, endowing the biomedical device with excellent superlubrication performance. N-Vinylpyrrolidone (NVP) and 2-methacryloyloxyethyl phosphorylcholine (MPC) are two typical representatives of nonionic and zwitterionic materials. However, there is still a research gap in a comparative study of the lubrication mechanisms and properties between them. In this study, a bioinspired and dopamine-assisted codeposition technique was used to fabricate biomimetic hydrophilic coatings, including P(DMA-NVP) and P(DMA-MPC), on polyurethane. To achieve a thorough comparative analysis of the self-adhesive coating performance, 3 M ratios of the copolymers were synthesized and comprehensive material evaluations were conducted. Additionally, surface morphology, hydrophilicity, and lubrication at both the microscale and macroscale were performed. It was found that both hydrophilic coatings exhibited good stability. The P(DMA-MPC) coating, due to the ability to attract and bind a large number of water molecules, demonstrated superior lubrication effects compared to the P(DMA-NVP) coating. The study provides an in-depth understanding of the lubrication behavior of the self-adhesive coatings to enhance the functionality and application in biomedical engineering.


Assuntos
Polímeros , Cimentos de Resina , Humanos , Lubrificação , Água
3.
PLoS One ; 19(4): e0301103, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38568980

RESUMO

Birch bark tar is the most widely documented adhesive in prehistoric Europe. More recent periods attest to a diversification in terms of the materials used as adhesives and their application. Some studies have shown that conifer resins and beeswax were added to produce compound adhesives. For the Iron Age, no comparative large-scale studies have been conducted to provide a wider perspective on adhesive technologies. To address this issue, we identify adhesive substances from the Iron Age in north-eastern France. We applied organic residue analysis to 65 samples from 16 archaeological sites. This included residues adhering to ceramics, from vessel surface coatings, repaired ceramics, vessel contents, and adhesive lumps. Our findings show that, even during the Iron Age in north-eastern France, birch bark tar is one of the best-preserved adhesive substances, used for at least 400 years. To a lesser extent, Pinaceae resin and beeswax were also identified. Through statistical analyses, we show that molecular composition differs in samples, correlating with adhesive function. This has implications for our understanding of birch bark tar production, processing and mode of use during the Iron Age in France and beyond.


Assuntos
Adesivos , Colagem Dentária , Adesivos/química , Betula/química , Resinas Vegetais , Arqueologia , Tecnologia , Teste de Materiais , Cimentos de Resina/química , Resinas Compostas/química
4.
J Adhes Dent ; 26(1): 103-116, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38602234

RESUMO

PURPOSE: To investigate the antibacterial effects of Terminalia catappa Linn (TCL) leaf extracts at different concentrations and the effects of these extracts used as primers on the long-term adhesive properties of two universal adhesives. MATERIALS AND METHODS: After extract preparation, the antimicrobial and antibacterial activities of TCL against Streptococcus mutans (UA 159) were assessed in microdilution assays to provide the minimal inhibitory concentration (MIC) and minimal bactericidal concentration (MBC). Additionally, to provide quantitative data on the ability of TCL extract to reduce cell viability, colony forming units (CFU) were counted. To examine adhesive properties, 288 human molars were randomly assigned to 32 experimental conditions (n = 9) according to the following variables: (1) treatment agent: negative control (untreated surface), and primers at concentrations of 1xMIC, 5xMIC, and 10xMIC; (2) adhesives: Scotchbond Universal (SBU) and Futurabond Universal (FBU); (3) adhesive strategy: etch-and-rinse (ER) or self-etch (SE); and (4) storage time: 24 h or after 2 years. Primers were applied for 60 s, upon which the teeth were incrementally restored and sectioned into adhesive-dentin bonded sticks. These were tested for microtensile bond strength (µTBS) and nanoleakage (NL) after 24-h and 2-year water storage, as well as in-situ degree of conversion (DC) at 24 h. The chemical profile of the hybrid layer was determined via micro-Raman spectroscopy. Biofilm assay data were analyzed using the Kruskal-Wallis test; the pH of culture media and the chemical profile were analyzed by one-way ANOVA. The adhesive properties (µTBS, NL, DC) were evaluated using a four-way ANOVA and Tukey's test. Significance was set at 5%. RESULTS: Similar values of MIC and MBC were observed (2 mg/ml), showing bactericidal potential. CFU analysis demonstrated that concentrations of 5xMIC and 10xMIC significantly inhibited biofilm formation (p < 0.001). The application of the TCL primer at all concentrations significantly increased the immediate µTBS and DC, and decreased the immediate NL values when compared to the control group (p < 0.05), regardless of the adhesive and adhesive strategies. Despite an increase in the NL values for all groups after 2 years (p > 0.05), in groups where the TCL primer was applied, the µTBS remained constant after 2 years for both adhesives, while a decrease in the µTBS was observed in the control groups (p < 0.05). Usually, 10xMIC showed better results than 1xMIC and 5xMIC (p < 0.05). The application of TCL promoted cross-linking; cross-linking rates increased proportionally to the concentration of TCL (p < 0.05). CONCLUSION: Primers containing TCL promoted bactericidal and bacteriostatic action, as well as cross-linking with dentin, while maintaining the adhesive properties of the adhesive-dentin interface after 2 years of water storage.


Assuntos
Colagem Dentária , Terminalia , Humanos , Cimentos Dentários/farmacologia , Cimentos Dentários/química , Adesivos Dentinários/farmacologia , Adesivos Dentinários/química , Resinas Compostas/química , Dentina , Resistência à Tração , Cimentos de Resina/farmacologia , Cimentos de Resina/química , Água/química , Antibacterianos/farmacologia , Teste de Materiais
5.
J Adhes Dent ; 26(1): 93-102, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38602286

RESUMO

PURPOSE: To investigate the influence of contamination and different cleaning methods on resin bonding to cobalt-chro- mium (CoCr) alloy disks. MATERIALS AND METHODS: A total of 160 CoCr disks were divided into 3 groups. The first group (N = 64) was air abraded with alumina particles and contaminated with a silicone disclosing agent and saliva; the second group (N = 64) was air abraded but not contaminated; the third group (N = 32) was neither air abraded nor contaminated. The first two groups were di- vided into 4 subgroups (N = 16) according to the cleaning method: ultrasonic bath in 99% isopropanol, use of a cleaning suspension of zirconium oxide particles, use of a cleaning suspension based on 10-MDP salt, and treatment with atmo- spheric plasma. The third group was divided into 2 subgroups (N = 16): treatment with atmospheric plasma and no treat- ment. All CoCr specimens were bonded to plexiglas tubes filled with a bonding resin that contained phosphate monomer. Tensile bond strength (TBS) was examined by tensile testing after 3 and 150 days of water storage plus 37,500 thermal cy- cles (N = 8). RESULTS: After contamination, TBS was significantly reduced after 150 days of water storage. Groups without air abrasion showed initially low TBS and debonded spontaneously after 150 days of water storage. CONCLUSION: None of the cleaning methods was able to remove saliva and silicone disclosing agent on CoCr-alloy sur- faces. Surface activation by plasma treatment has no long-term effect on the bond strength.


Assuntos
Resinas Compostas , Colagem Dentária , Cimentos de Resina , Ligas , Abrasão Dental por Ar , Propriedades de Superfície , Água , Resistência à Tração , Silicones , Teste de Materiais , Zircônio , Análise do Estresse Dentário
6.
BMC Oral Health ; 24(1): 423, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580948

RESUMO

BACKGROUND: To evaluate the physical properties of bioactive glass-modified universal multimode adhesive and its micro-tensile bond strength (µTBS) to artificially induced caries-affected dentin. METHODS: All bond universal adhesive was used in the study. Specimens were divided into 2 main groups: control unmodified adhesive and 5 wt% BAG modified adhesive. The degree of conversion, pH, bioactivity, and viscosity of the adhesives were tested with n = 5 for each test. Micro-tensile bond strength evaluation was done in etch & rinse (ER) and selective-etch (SE) modes, where 24 human molar teeth were used (n = 3), 12 teeth for immediate bond strength, and the other 12 were tested after 6 months of storage in simulated body fluid (SBF). RESULTS: No significant difference was found between the control and the 5wt% BAG groups regarding the degree of conversion (61.01 ± 0.43 and 60.44 ± 0.61 respectively) and the viscosity (109.77 ± 22.3 and 124.3 ± 9.92 respectively). The control group revealed significantly lower pH values than the 5wt% BAG group (3.16 ± 0.5 and 4.26 ± 0.09 respectively). Immediate bond strength results revealed that the 5wt% BAG in the ER mode had the highest bond strength followed by the control group in the ER mode (44.16 ± 7.53 and 44.00 ± 7.96 respectively). SE groups showed that the immediate strength of the 5wt% BAG group was higher than the control group (42.09 ± 6.02 and 39.29 ± 6.64 respectively). After 6 months of storage, bond strength results revealed a decrease in bond strength values for the control groups but not for the 5wt% BAG in both application modes. CONCLUSIONS: The incorporation of BAG (5wt%) improved the universal adhesive micro-tensile bond strength and bond durability for both adhesive application modes without affecting its degree of conversion or viscosity.


Assuntos
Colagem Dentária , Cárie Dentária , Humanos , Cimentos Dentários , Adesivos Dentinários/química , Cimentos de Resina/química , Suscetibilidade à Cárie Dentária , Teste de Materiais , Resistência à Tração , Dentina
7.
Shanghai Kou Qiang Yi Xue ; 33(1): 36-39, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38583022

RESUMO

PURPOSE: To study the effect of different cleaning methods on the shear bond strength of self-adhesive resin cement to saliva-contaminated high translucency zirconia and surface wettability. METHODS: Eighty zirconia specimens were randomly divided into 5 groups (n=16), i.e., control group(not contaminated), 75% ethanol group,cleaning paste group,airborne-particle abrasion group, and atmospheric pressure cold plasma group. The contact angles was measured, shear bond strength were examined, and fracture types were determined. SPSS 26.0 software package was used for statistical analysis of the data. RESULTS: The atmospheric pressure cold plasma group produced the lowest contact angle(P<0.05). The shear bond strength of the airborne-particle abrasion group, the cleaning paste group and the atmospheric pressure cold plasma group respectively were similar to the control group without significant difference(P>0.05), while those were significantly higher than 75% ethanol group(P<0.05). The mixed fracture mode of the atmospheric pressure cold plasma group evidently increased. CONCLUSIONS: Airborne-particle abrasion, cleaning paste and atmospheric pressure cold plasma overcome the effects of saliva contamination, producing the shear bond strength to zirconia similar to the control group. The atmospheric pressure cold plasma improves hydrophilicity of high translucency zirconia significantly.


Assuntos
Colagem Dentária , Gases em Plasma , Molhabilidade , Propriedades de Superfície , Cimentos de Resina , Zircônio/química , Etanol , Teste de Materiais , Resistência ao Cisalhamento , Análise do Estresse Dentário
8.
Biomed Res Int ; 2024: 7720286, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577705

RESUMO

Background: Zirconia, with its excellent mechanical properties, has become a popular choice for esthetic and durable restorations due to the increasing demand of patients. It has overcome most of the limitations of all ceramic restorations. However, bonding to zirconia remains a challenge. Objectives: This study is aimed at assessing the effect of surface treatment with alkaline agents at two different temperatures on microshear bond strength (µSBS) of zirconia to composite resin. Materials and Methods: This in vitro, experimental study was conducted on zirconia blocks measuring 2 × 4 × 8 mm. The blocks were sandblasted with alumina powder and randomly assigned to 5 groups (n = 16 each). The blocks in groups 1 and 2 underwent surface treatment with sodium hydroxide (NaOH) and groups 3 and 4 with zirconium hydroxide (Zr(OH)4) at room temperature and 70°C. Group 5 served as the control group and did not receive any surface treatment. After the application of bonding agent and its light-curing, composite cylinders in plastic tubes were bonded to the surface of each block and cured. After incubation, they underwent µSBS test. Data were analyzed by one-way ANOVA and Tukey's test (alpha = 0.05). Results: The µSBS was significantly higher in all intervention groups than that in the control group (P < 0.05). The µSBS in Zr(OH)4 groups was significantly higher than that in NaOH groups (P < 0.05). The mean µSBS of heated groups was slightly, but not significantly, higher than the corresponding room temperature groups (P > 0.05). Conclusion: Surface treatment of zirconia with NaOH and Zr(OH)4 alkaline agents can increase its µSBS to composite resin; Zr(OH)4 was significantly more effective than NAOH for this purpose, but heating did not have a significant effect on µSBS.


Assuntos
Resinas Compostas , Colagem Dentária , Humanos , Resinas Compostas/química , Propriedades de Superfície , Cimentos de Resina/química , Temperatura , Hidróxido de Sódio , Teste de Materiais , Zircônio/química , Cerâmica/química , Resistência ao Cisalhamento
9.
Med Sci Monit ; 30: e943502, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38515376

RESUMO

BACKGROUND Modification of the glass fiber post (GFP) with titanium dioxide or silver particles can improve the durability and reliability of dental treatments for ensuring long-term success. This research assessed the tensile bond strength (TBS) of an adhesive system used for cementing GFPs into root dentin following the incorporation of nanoparticles of titanium dioxide (NTiO2) and silver (NAg). MATERIAL AND METHODS Sixty human maxillary canines were prepared to create a 10-mm intra-radicular space for post placement from the cementoenamel junction. The specimens were randomly allocated into 2 groups (a non-thermocycling group and a thermocycling group). Each group was divided into 3 subgroups (10 samples each) according to the adhesive system used (adhesive system devoid of any addition, adhesive system including 1% NAg, and adhesive system infused with 1% NTiO2). TBS tests were conducted and recorded in MPa using a Universal Testing Machine, with an axial load applied at a rate of 0.5 mm/min until failure. The TBS for both groups (non-thermocycling and thermocycling) was measured in megapascals (MPa), and the failure type was recorded. The data were statistically analyzed using one-way analysis of variance (ANOVA) and Tukey's test with P.


Assuntos
Adesivos , Colagem Dentária , Vidro , Titânio , Humanos , Cimentos de Resina/química , Resistência à Tração , Reprodutibilidade dos Testes , Prata , Dentina , Teste de Materiais
10.
Niger J Clin Pract ; 27(3): 304-309, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38528349

RESUMO

BACKGROUND AND AIM: Gastroesophageal reflux disease causes gastric acid to enter the oral cavity, leading to mucosal changes and deterioration of dental hard tissues and materials. The purpose of this in vitro study was to evaluate the impact of gastric juice on the surface roughness of two types of acrylics used in provisional restorations. MATERIALS AND METHODS: Acrytemp ® and Temdent acrylic resin discs (10 × 2 mm) totaling 80 were manufactured and divided into eight groups (n = 10). Groups were prepared as follows: Group 1 (Temdent + Universal Polish) (control), Group 2 (Temdent + Universal Polish + Biscover LV), Group 3 (Temdent + Universal Polish + Resin Glaze), Group 4 (Temdent + Universal Polish + Fortify Plus), Group 5 (Acrytemp + Universal Polish) (control), Group 6 (Acrytemp + Universal Polish + Biscover LV), Group 7 (Acrytemp + Universal Polish + Resin Glaze), and Group 8 (Acrytemp + Universal Polish + Fortify Plus). The resin discs were immersed in distilled water for 24 h and in gastric juice (pH = 2) for additional 24 h. The initial and final roughness values of samples were measured and analyzed with non-parametric statistics including Mann-Whitney U-test for pairwise comparison, Kruskall Wallis test for comparing more than two groups, and Wilcoxon signed rank test for within-group comparison (P < 0.05). RESULTS: Surface roughness did not differ significantly between control groups. It notably increased for all samples with surface sealants, both initially and after gastric juice immersion (P < 0.05). CONCLUSION: Surface sealants noticeably increased the roughness of two types of acrylic resins. After immersing in gastric juice, Group 4 (Temdent + Universal Polish + Fortify Plus) showed the highest roughness, while the untreated control groups remained the smoothest.


Assuntos
Acrilatos , Resinas Acrílicas , Resinas Compostas , Cimentos de Resina , Humanos , Propriedades de Superfície , Teste de Materiais , Suco Gástrico , Materiais Dentários
11.
J Adhes Dent ; 26(1): 79-86, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38465402

RESUMO

PURPOSE: This investigation aimed to assess the impact of additive manufacturing-generated surface textures on zirconia bond strength. MATERIALS AND METHODS: Zirconia samples (n = 144) fabricated using digital light-processing (DLP) technology were categorized into 6 groups according to the type of surface conditioning (group NN: no designs, no air abrasion; group NY: no designs, with air abrasion; group GN: groove designs, no air abrasion; group GY: groove designs with air abrasion; group HN: hexagon grid, no air abrasion; group HY: hexagon grid, with air abrasion). Composite resin cylinders were cemented to the treated zirconia surfaces with dual-curing, self-adhesive resin cement (Clearfil SA Luting). The shear bond strength (SBS) was tested after water storage for 3 days or 3 days with an additional 10,000 thermocycles. RESULTS: The zirconia samples fabricated using DLP technology have high accuracy. The SBS of the NY, GY, and HY groups did not significantly differ after 3 days, and neither did the SBS of the NN, GN, and HN groups. The NN, NY, and HY groups exhibited reduced SBS compared to their initial values following artificial aging, while the SBS of the remaining three groups were not diminished. The GY group obtained the highest SBS value after aging. CONCLUSION: Printing grooves with air abrasion can improve the bond strength.


Assuntos
Colagem Dentária , Abrasão Dental por Ar , Propriedades de Superfície , Cimentos de Resina/química , Resinas Compostas , Resistência ao Cisalhamento , Zircônio/química , Teste de Materiais , Análise do Estresse Dentário
12.
J Adhes Dent ; 26(1): 87-92, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38465403

RESUMO

PURPOSE: This paper describes previously unknown details about the discovery of resin adhesion to acid-etched human enamel. MATERIALS AND METHODS: A literature review was performed through manual assessments. Primary sources revealing the discovery of resin curing on etched enamel were analyzed considering the research objectives and methodological procedure during that era, including the type of teeth used, preparatory measures, acid-etching process, type of resin and its application, and follow-up observations. Additionally, the political and economic contexts were examined. RESULTS: In 1949, acid etching was found to promote adhesion with acrylic resin, a finding described again in 1955. The 1949 studies utilized nitric acid for enamel etching and the acrylate resin Paladon from the Kulzer company (Germany). Conversely, the 1955 investigations employed phosphoric acid and an unnamed acrylate, likely a self-curing resin supported by Kulzer in the late 1930s. Disparities in the 1949 and 1955 findings can be ascribed to varying objectives and test conditions amidst a turbulent political backdrop, significantly impacting the Kulzer company. CONCLUSION: The discovery of resin adhesion to acid-etched enamel, approaching its 75th anniversary in 2024, is a landmark in 20th-century adhesive dentistry. Paladon represents a pioneering compound, exemplifying the influence of political, ideological, and economic factors on scientific advancements during that period.


Assuntos
Colagem Dentária , Humanos , Condicionamento Ácido do Dente/métodos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Esmalte Dentário , Ácidos Fosfóricos , Acrilatos , Cimentos de Resina , Teste de Materiais
13.
Int J Biol Macromol ; 265(Pt 2): 131143, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38537861

RESUMO

Hydrogel electrolyte is an ideal candidate material for flexible energy storage devices due to its excellent softness and conductivity properties. However, challenges such as the inherent mechanical weakness, the susceptibility to be frozen in low-temperature environments, and the insufficiency of hydrogel-electrode contact persist. Herein, a "Multi in One" strategy is employed to effectively conquer these difficulties by endowing hydrogels with high strength, freeze-resistance, and self-adhesive ability. Multiple hydrogen bond networks and ion crosslinking networks are constructed within the hydrogel electrolyte (PVA/PAAc/XG) containing polyvinyl alcohol (PVA), acrylic acid (AAc), and xanthan gum (XG), promoting the enhanced mechanical property, and the adhesion to electrode materials is also improved through abundant active groups. The introduction of zinc ions provides the material with superior frost resistance while also promoting electrical conductivity. Leveraging its multifunction of superior mechanical strength, anti-freeze property, and self-adhesive characteristic, the PVA/PAAc/XG hydrogel electrolyte is employed to fabricate zinc ion hybrid supercapacitors (ZHS). Remarkably, ZHS exhibits outstanding electrochemical performance and cycle stability. A remarkable capacity retention rate of 83.86 % after 10,000 charge-discharge cycles can be achieved at high current densities, even when the operational temperature decreases to -60 °C, showing great potential in the field of flexible energy storage devices.


Assuntos
Polissacarídeos Bacterianos , Cimentos de Resina , Zinco , Hidrogéis , Eletrólitos , Íons
14.
Arch Oral Biol ; 162: 105942, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38452415

RESUMO

OBJECTIVES: The aim of this scoping review was to evaluate the available scientific evidence regarding the use of flavonoids in the treatment of caries-affected dentin focusing on bonding to dentin. METHODS: A comprehensive literature search was performed in five databases from March 2022 and updated in April 2023: PubMed, EMBASE, Scopus, Web of Science, and Scielo. Additionally, the references of included studies were manually searched. Gray literature was excluded from the review. STUDY SELECTION: Inclusion criteria included in vitro, in situ, and in vivo studies (animal or human) published in English. Abstracts, reviews, case reports, book chapters, doctoral dissertations, guidelines, and studies using pure plant extracts were excluded. Data collected from the selected studies were summarized and subjected to narrative and descriptive analysis. Out of the 91 studies identified, only 16 studies met the inclusion criteria. RESULTS: The review analyzed eight different flavonoids (hesperidin, galardin, proanthocyanidin, genipin, quercetin, naringin, epigallocatechin-3-gallate, and other catechins subtypes) used as pretreatment or loaded into adhesive systems, primers, and phosphoric acid. The use of flavonoids improved the mechanical properties of the materials and modified the biological properties of the dentin, reducing collagen loss by the inhibition of proteolytic activity of matrix metalloproteinases (MMPs). CONCLUSIONS: Based on the findings of this scoping review, it can be concluded that the use of flavonoids as pretreatment or incorporation into dental materials preserves collagen in the hybrid layer, inhibiting the MMPs activities, modifying the collagen fibrils of the dentin matrix and improving the mechanical properties of the dental adhesive systems. Therefore, it represents a promising approach for promoting dentin biomodification. This can result in more stable bonding of adhesive restorations to caries-affected dentin.


Assuntos
Colagem Dentária , Cárie Dentária , Humanos , Flavonoides/farmacologia , Suscetibilidade à Cárie Dentária , Colágeno , Cárie Dentária/tratamento farmacológico , Metaloproteinases da Matriz , Dentina , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Resistência à Tração
15.
BMC Oral Health ; 24(1): 402, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553692

RESUMO

OBJECTIVES: The aim of the present study was to evaluate the effect of chitosan and carboxymethyl chitosan (CMCS) on dentin surface morphology and bonding strength after irradiation of Er:YAG laser. METHODS: Eighty-four laser-irradiated dentin samples were randomly distributed into three groups (n = 28/group) according to different surface conditioning process: deionized water for 60s; 1wt% chitosan for 60s; or 1wt% CMCS for 60s. Two specimens from each group were subjected to TEM analysis to confirm the presence of extrafibrillar demineralization on dentin fibrils. Two specimens from each group were subjected to morphological analysis by SEM. Seventy-two specimens (n = 24/group) were prepared, with a composite resin cone adhered to the dentin surface, and were then randomly assigned to one of two aging processes: storage in deionized water for 24 h or a thermocycling stimulation. The shear bond strength of laser-irradiated dentin to the resin composite was determined by a universal testing machine. Data acquired in the shear bond strength test was analyzed by one-way ANOVA with the Tukey honestly significant difference post hoc test and Independent Samples t-test (α = 0.05). RESULTS: CMCS group presented demineralized zone and a relatively smooth dentin surface morphology. CMCS group had significantly higher SBS value (6.08 ± 2.12) without aging (p < 0.05). After thermal cycling, both chitosan (5.26 ± 2.30) and CMCS group (5.82 ± 1.90) presented higher bonding strength compared to control group (3.19 ± 1.32) (p < 0.05). Chitosan and CMCS group preserved the bonding strength after aging process (p > 0.05). CONCLUSIONS: CMCS has the potential to be applied in conjunction with Er:YAG laser in cavity preparation and resin restoration.


Assuntos
Quitosana , Colagem Dentária , Lasers de Estado Sólido , Humanos , Lasers de Estado Sólido/uso terapêutico , Quitosana/farmacologia , Resinas Compostas/química , Resistência ao Cisalhamento , Dentina , Água/química , Cimentos de Resina/análise
16.
Dent Mater J ; 43(2): 312-319, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38432950

RESUMO

We examined how different methods of surface treatment and different universal adhesives with or without extra silane affected the repair bonding strength of hybrid ceramic CAD/CAM restorations. Cerasmart specimens (n=320) were subjected to thermocycling and assigned to the following surface pretreatment protocols: control, diamond bur (DB), hydrofluoric acid (HF), and tribochemical silica coating (TSC). Half the specimens received a coating of silane, followed by application of the universal adhesives Futurabond M+ (FMU), Tokuyama Universal Bond (TUB), Single Bond Universal (SBU), or Clearfil Universal Bond Quick (CUQ) (n=10). A hybrid composite resin was used to simulate repair; then the specimens underwent further thermocycling. Shear bond strength (SBS) was determined and modes of failure were examined. The TSC-CUQ silane (-) group showed the highest SBS values. The best repairs were obtained when the surface was treated with TSC, with the exception of the DB-TUB silane (-) group. TUB increased SBS more than the other adhesives. Additional silane decreased SBS in the HF-TUB and TSC-CUQ groups, while increasing it in the TSC-TUB and DB-FMU groups (p<0.05).


Assuntos
Colagem Dentária , Silanos , Silanos/química , Cimentos Dentários , Propriedades de Superfície , Teste de Materiais , Cerâmica/química , Resistência ao Cisalhamento , Cimentos de Resina/química
17.
Dent Mater J ; 43(2): 303-311, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38447979

RESUMO

This study evaluated the bonding performance of coronal dentin disks, designed for biological restoration, and CAD/CAM resin composite disks when bonded to flat dentin surfaces using dual-cure resin cements, with and without a resin-coating (RC) technique. Three distinct groups were established within the non-RC group, each using one of the two types of resin cements in a self-adhesive mode: one-step self-etch adhesive (1-SEA) without light-cure, 1-SEA with light-cure, and a separate group using an alternate cement. Within the RC group, a subgroup was established for each cement. The microtensile bond strength (µTBS) of the disk-dentin beam was tested after 0 and 10,000 thermocycles in a 5°C/55°C. No significant µTBS difference was observed among the non-RC groups. However, when using RC, the µTBSs of coronal dentin disks significantly exceeded those of CAD/CAM resin composite disks. Thermocycle aging did not affect µTBS in any of the bonding methods, except in self-adhesive mode.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Cimentos Dentários , Colagem Dentária/métodos , Resistência à Tração , Teste de Materiais , Resinas Compostas/química , Adesivos Dentinários/química , Cimentos de Ionômeros de Vidro , Dentina
18.
J Clin Pediatr Dent ; 48(2): 19-25, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38548629

RESUMO

This study aims to investigate the impact of storage conditions for crown fragments (specifically, whether they were stored within a tooth rescue box or in tap water) on their adhesion to fractured teeth when subjected to two different adhesive systems (namely, total etch and self etch). Sixty maxillary premolars were sectioned to obtain tooth fragments. These fragments were stored briefly (2 hours) and reattached in the following groups: Group 1 (fragments stored in tooth rescue box and reattached with etch and rinse (E&R) technique), Group 2 (fragments stored in tap water and reattached with E&R technique), Group 3 (fragments stored in tooth rescue box and reattached with self-etch (SE) technique), and Group 4 (fragments stored in tap water and reattached SE technique). After reattachment, the bonded tooth fragments underwent thermal cycling (500 cycles, 5-55 °C) and bond strength testing using a universal testing machine. Two-way Analysis of Variance (ANOVA) and Tukey's tests were used for bond strength comparison (p ≤ 0.05). A two-parameter Weibull distribution was conducted to evaluate the reliability of the storage medium and adhesion modality on bond strength. The results showed that measured shear bond values (MPa ± Standard deviation (SD); arranged in descending order) for each group were: Group 2 (Tap water/E&R = 6.5 ± 2.1), Group 1 (Rescue box/E&R = 6.0 ± 2.5), Group 4 (Tap water/E&R = 5.1 ± 2.8), and Group 3 (Rescue box/SE = 3.6 ± 3.2). Significant differences were found only between Groups 2 and 3 (p = 0.002). In conclusion, storing crown fragments in a tooth rescue box did not significantly affect the shear bond strength of the restored tooth. However, fragments reattached using the self-etch technique showed comparable shear bond strength but a higher rate of adhesive failures compared to the E&R technique.


Assuntos
Colagem Dentária , Fraturas dos Dentes , Humanos , Reprodutibilidade dos Testes , Resinas Compostas/química , Resinas Compostas/farmacologia , Água/farmacologia , Colagem Dentária/métodos , Cimentos de Resina/química , Cimentos de Resina/farmacologia , Teste de Materiais , Resistência ao Cisalhamento , Adesivos Dentinários/química , Adesivos Dentinários/farmacologia , Dentina
19.
BMC Oral Health ; 24(1): 323, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468269

RESUMO

OBJECTIVE: This study was conducted to assess the influence of combining different forms of fiber-reinforced composites (FRC) on the mechanical behavior and bond strength of compromised endodontically treated teeth (ETT). MATERIALS AND METHODS: Eighty extracted human premolar teeth were randomly divided into five experimental groups according to the type of intra-radicular restoration and the canal preparation design which was either non-flared (Group 1), flared (Groups 2-5), closed-apex (Groups 1,3,5) or open-apex (Groups 2,4). Standard prefabricated fiber posts were used as intra-radicular restoration for Groups 1-3 while Groups 4-5 were restored with anatomically customized relined fiber posts. After composite core fabrication, all samples were sent for an artificial aging process. Fracture resistance and push-out bond strength tests were then carried out through a universal testing machine followed by mode of failure analysis via a stereomicroscope and scanning electron microscope. RESULTS: Pairwise Log-Rank comparisons revealed that the survival rate of Group 2 and Group 3 was significantly lower than all other groups after artificial aging. The highest fracture resistance value (1796 N) was recorded in Group 5 and was significantly higher than that of the other groups (p < 0.05), while Group 2 exhibited the lowest fracture resistance (758 N), which was significantly lower compared to the other groups. Group 5 and Group 4 demonstrated a significantly higher push-out bond strength, at all root thirds, than Group 3, Group 2, and Group 1 (p < 0.05). The most frequently observed failure mode in the tested groups occurred between the resin cement and radicular dentin. CONCLUSION: The use of short fiber-reinforced composite (SFRC) to reline the prefabricated FRC post has been proven to have superior fracture resistance with favorable failure patterns and increased push-out bond strength values compared to standard prefabricated FRC posts.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Resinas Compostas/química , Dente Pré-Molar , Cimentos de Resina/química , Teste de Materiais , Análise do Estresse Dentário , Fraturas dos Dentes/prevenção & controle
20.
Clin Oral Investig ; 28(3): 207, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459231

RESUMO

OBJECTIVE: To compare the clinical performance of a glass hybrid (GH) restorative and a nano-ceramic composite resin (CR) in the restoration of non-carious cervical lesions (NCCLs) of bruxist individuals in a 60-month randomized clinical trial. MATERIALS AND METHODS: Twenty-five bruxist candidates having NCCLs were recruited in this clinical study. The depth, height (cervico-incisal), width (mesio-distal), internal angles of the NCCLs, degree of tooth wear (TWI) and gingival index (GI) were measured. One hundred-and-forty-eight NCCLs were restored either with a GH restorative (Equia Forte Fil) or a CR (Ceram.X One Universal). Modified USPHS criteria was used to evaluate restorations after 1 week and 12, 24, 36 and 60 months. Pearson's Chi-Square, Fisher's Exact and Cochran Q tests were run for analysis. Survival rates of the restorations were compared with Kaplan-Meier analysis (p < 0.05). RESULTS: After 60 months, 97 restorations in 15 patients were examined. The recall rate was 60.0%. Retention rates were 73.5% for CR and 66.7% for GH. A total of 29 restorations were lost (13CR (26.5%), 16GH (33.3%)). There was not a significant difference between tested restoratives in retention (p = 0.464), marginal adaptation (p = 0.856) and marginal discoloration (p = 0.273). There was no relationship between internal angle, depth, height or width and retention of the GH or CR restorations (p > 0.05). The increase in retention loss and marginal discoloration of both restorations over time were significant (p < 0.001). Sensitivity or secondary caries were not detected after 60 months. CONCLUSION: GH and nano-ceramic CR showed similar clinical performances in NCCLs after 60 months in patients with bruxism. CLINICAL SIGNIFICANCE: After 60 months, CR and GH materials showed clinically acceptable performances in restoration of NCCLs in patients with bruxism.


Assuntos
Bruxismo , Cárie Dentária , Humanos , Restauração Dentária Permanente , Colo do Dente/patologia , Resinas Compostas , Cárie Dentária/patologia , Adaptação Marginal Dentária , Cimentos de Resina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...